EHIKPUMPS
Menu

Chemical Processing / High-Head Liquid Duties

High‑Head Pumps for Chemical Processes

High head at low flow for continuous process feed, solvent circulation and liquid transfer. EHIK matches the pump, materials, inlet-side mechanical seal and drive to your liquid and operating conditions, and supplies them as one package.

New process unitsCapacity changesPump replacement
Two blue EHIK pumps connected to pipework and valves at a urea hydrolysis feed installation.
Urea Hydrolysis FeedEHIK pitot tube pumps supplying liquid feed to a urea hydrolysis process.

Where EHIK Fits

High Head for Feed,
Circulation & Transfer.

A high-pressure process does not always need a large flow. EHIK matches the pump to what each liquid circuit needs.

Continuous Process Feed

Feed liquid into a process that is under pressure. EHIK's urea hydrolysis installation is an example, with pump sets connected directly to the process pipework.

Solvent & Process-Liquid Circulation

Keep liquid moving around the process circuit at the flow and head you need. EHIK's applications include solvent circulation in natural-gas purification.

High-Head Liquid Transfer

Move process liquids between vessels or into a pressurized system. EHIK's selection includes vessel pressures, height differences and piping losses.

Existing-Unit Upgrades

Solve repeated loss of prime, wear, seal problems or a changed production duty. At the Daqing methanol workshop below, an EHIK replacement brought back stable delivery.

Field Experience

Urea Feed, Plant Retrofits
& Methanol Service.

The urea installation above is a process-feed example. Below are two more projects: a multistage-pump replacement at Jingbao Xinao and a delivery problem solved in a Daqing methanol workshop.

EHIK pump sets installed among existing chemical-process piping at Jingbao Xinao Chemical.
Pump installation at Jingbao Xinao Chemical, China.

Jingbao Xinao Chemical / Retrofit Reference

New Pump Sets.
Existing Process Pipework.

In 2023–2024, EHIK replaced multistage pumps at Jingbao Xinao Chemical. The installed pump sets connect with the plant's process pipework, valves and instruments.

A plant upgrade must fit both the duty and the space. We plan the duty, connection positions, drive footprint and operating access together. Custom flanges can match your existing piping.

Close view of an EHIK pump, motor, coupling guard, instruments and connected piping at Jingbao Xinao.
Jingbao Xinao: a closer view of the pump, drive and process connections.

Make Space for Operation
and Equipment Access.

The drive, coupling guard, instruments and process connections share the same space. Their layout matters to the people who operate and maintain the unit.

EHIK's outline drawings show nozzle positions, motor footprint and access space before delivery. Your team can then plan the pipework and installation, for a new unit or an existing plant.

Contact EHIK

Daqing Methanol Workshop / 2009

Stable Delivery After a Multistage Pump Replacement.

At Daqing Oilfield Chemical Group's methanol workshop, the old multistage pump had severe cavitation, often lost prime and delivered an unsteady flow.

EHIK replaced the pump in 2009. Our project records show stable operation after the change.

From Chemistry to Configuration

Select More Than
a Flow and a Pressure.

The liquid data and operating range decide the materials, mechanical seal, drive and supporting equipment.

Composition & Concentration

The main liquid, dissolved chemicals, contaminants and changes in concentration between production and cleaning decide the material and seal.

Temperature & Viscosity

Normal and startup temperatures and viscosity affect the duty, motor load and seal conditions.

Inlet & Vapor Pressure

Feed-vessel pressure, liquid level and suction pipework decide the inlet conditions. This is important for hot liquids or liquids that vaporize easily.

Particles & Crystallization

Solids, deposits and crystals that form when the liquid cools or the pump stops affect wear and sealing. EHIK uses operating experience to match the pump to these conditions.

Control & Operating Range

Minimum, normal and maximum flow, pressure control and startup needs decide the pump and controls. Precise dosing needs a separate assessment.

Materials, Seals & Site

EHIK's proposal covers materials, seal, motor and site connections, and follows your plant's equipment requirements.

Why the Pump Design Matters

High Head.
Matched to Your Liquid.

EHIK designs and manufactures the pump and can supply the drive, base and supporting equipment as a coordinated package.

EHIK pump equipment with a vertical seal-support vessel and connected pipework.
EHIK equipment with seal-support components—a configuration example.

High Head in One Stage

A rotating casing and stationary pickup tube create high head in one stage. The flow is continuous, with no back-and-forth pumping strokes.

A Seal on the Inlet Side

EHIK places the mechanical seal on the inlet side, away from the high-pressure discharge. The seal and its support arrangement are selected for the actual chemistry, temperature and inlet pressure.

A Defined Supply Package

Choose a bare-shaft pump, a complete pump set with motor and base, or a skid with the required instruments, valves, pipework and controls. Agree the supply scope early, so your site team knows what arrives assembled.

EHIK also supplies pickup tubes and rotor assemblies, with drawings available to confirm spare-part matching.

Chemical Pump FAQs

Support for Your
Chemical Pumping Duty.

The liquid name is only a start. Its composition, operating conditions and system needs make the selection right for your plant.

Which chemical-process duties does EHIK cover?

EHIK supplies pumps for high-head, relatively low-flow liquid duties, including process feed, circulation and transfer. Documented applications include urea hydrolysis feed and solvent circulation. Contact EHIK for help with your chemical pumping application.

Can you select materials from the chemical name alone?

No, the chemical name alone is not enough. Composition, concentration, temperature and contaminants affect the material and seal. EHIK helps you check these.

Can a pitot tube pump replace a metering pump?

Continuous delivery and precise metering are different needs. A steady feed and an exact dosing accuracy or turndown are assessed differently. EHIK checks the pump and controls against your process.

How are hot or volatile liquids considered?

Liquid temperature, vapor pressure, supply-vessel pressure and level, and suction-line layout affect the inlet conditions and seal support. EHIK considers startup and shutdown as well as normal operation.

Can you review a problematic existing pump?

Yes. Contact EHIK for help with an existing pump. We look at the operating problem, check wear or seal issues and review the duty and fit for a replacement. Custom flanges can match your existing piping.

Do I need a complete specification before contacting EHIK?

No. Contact EHIK directly and include any liquid properties, flow or pressure you know. We reply within 1 business day. We can help develop the selection and provide performance curves, outline drawings and technical support.

Start a New Project

Let's Discuss Your Chemical Pump.

Contact EHIK for help with process feed, circulation or liquid transfer. We can match the pump, materials and sealing arrangement to your chemical duty.

Contact EHIK

EHIK also helps with pump replacements and recurring operating problems.

Pump Selection

A proposed pump and configuration for the liquid duty.

Performance Curves

To check the pump against your process needs.

Outline Drawings

Dimensions and interfaces for your installation layout.

Technical Support

Help with materials, seals, controls and supply scope.